{"id":1672,"date":"2026-09-20T22:53:48","date_gmt":"2026-09-20T14:53:48","guid":{"rendered":"https:\/\/www.zzanwke.com\/?post_type=cxb_products&#038;p=1672"},"modified":"2026-09-28T18:08:20","modified_gmt":"2026-09-28T10:08:20","slug":"ggd1-ggd2-ggd3-ac-low-voltage-distribution-cabinet-feeder-cabinet","status":"publish","type":"cxb_products","link":"https:\/\/www.zzanwke.com\/ja\/products\/ggd1-ggd2-ggd3-ac-low-voltage-distribution-cabinet-feeder-cabinet\/","title":{"rendered":"GGD1\/GGD2\/GGD3 AC Low-Voltage Distribution Cabinet (Feeder Cabinet)"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"700\" height=\"393\" src=\"https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/10kV_0.4kV\u4ea4\u6d41\u4f4e\u538b\uff08\u9988\u7ebf\u67dc\uff09\u6280\u672f\u56fe.png\" alt=\"\" class=\"wp-image-1994\" srcset=\"https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/10kV_0.4kV\u4ea4\u6d41\u4f4e\u538b\uff08\u9988\u7ebf\u67dc\uff09\u6280\u672f\u56fe.png 700w, https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/10kV_0.4kV\u4ea4\u6d41\u4f4e\u538b\uff08\u9988\u7ebf\u67dc\uff09\u6280\u672f\u56fe-18x10.png 18w, https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/10kV_0.4kV\u4ea4\u6d41\u4f4e\u538b\uff08\u9988\u7ebf\u67dc\uff09\u6280\u672f\u56fe-500x281.png 500w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"700\" height=\"393\" src=\"https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/10kV_0.4k\u4ea4\u6d41\u4f4e\u538b\uff08\u9988\u7ebf\u67dc\uff09\u5b89\u88c5\u56fe.png\" alt=\"\" class=\"wp-image-1992\" srcset=\"https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/10kV_0.4k\u4ea4\u6d41\u4f4e\u538b\uff08\u9988\u7ebf\u67dc\uff09\u5b89\u88c5\u56fe.png 700w, https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/10kV_0.4k\u4ea4\u6d41\u4f4e\u538b\uff08\u9988\u7ebf\u67dc\uff09\u5b89\u88c5\u56fe-18x10.png 18w, https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/10kV_0.4k\u4ea4\u6d41\u4f4e\u538b\uff08\u9988\u7ebf\u67dc\uff09\u5b89\u88c5\u56fe-500x281.png 500w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<h1 class=\"wp-block-heading\">GGD1\/GGD2\/GGD3 AC Low-Voltage Power Distribution Cabinet (Feeder Cabinet)<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">1. Product Overview<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">GGD series feeder cabinet is fixed-type low-voltage distribution switchgear for AC 50\/60Hz, 400V three-phase four-wire systems, complying with IEC 60439-1 and GB 7251.1 standardsMade-in-Ch&#8230;. It adopts rigid 8MF cold-bent steel frame with IP30 protection grade, matched with main incoming, bus coupler and compensation cabinets. Its core function is to divide main bus power into multiple independent outgoing branches, supplying power to workshop equipment, lighting, building power distribution boxes and motor loads, with independent overload, short-circuit and leakage protection for each circuit. GGD1, GGD2 and GGD3 differ in short-circuit withstand capacity and bus carrying current to cover small, medium and large load distribution projects worldwide.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Standard Internal Configuration<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Molded Case Circuit Breaker (MCCB): Each outgoing loop is equipped with MCCB for branch fault isolation; optional leakage protection modules.<\/li>\n\n\n\n<li>Current Transformer (CT): Matched with ammeters and multi-function meters to monitor branch current and power consumption.<\/li>\n\n\n\n<li>Main Copper Busbar System: Top-through L1\/L2\/L3 phase busbars, separate N neutral busbar and PE grounding busbar; all joints are tinned to reduce contact resistance.<\/li>\n\n\n\n<li>Measuring &amp; Indication Panel: Ammeter, running\/fault indicator lights for real-time branch status observation.<\/li>\n\n\n\n<li>Secondary Terminal Block: Centralized wiring for remote signal transmission and monitoring communication.<\/li>\n\n\n\n<li>Cable Compartment: Bottom cable inlet and outlet, convenient for laying power cables to terminal loads.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">3. Technical Parameter Comparison<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Specification Item<\/strong><strong><\/strong><\/td><td><strong>GGD1 Feeder Cabinet<\/strong><strong><\/strong><\/td><td><strong>GGD2 Feeder Cabinet<\/strong><strong><\/strong><\/td><td><strong>GGD3 Feeder Cabinet<\/strong><strong><\/strong><\/td><\/tr><\/thead><tbody><tr><td>Rated AC Voltage<\/td><td>400V, 50\/60Hz<\/td><td>400V, 50\/60Hz<\/td><td>400V, 50\/60Hz<\/td><\/tr><tr><td>Max Main Bus Current<\/td><td>\u22641000A<\/td><td>\u22641500A<\/td><td>\u22643150A<\/td><\/tr><tr><td>1s Short-Time Withstand Current<\/td><td>15kA<\/td><td>30kA<\/td><td>50kA<\/td><\/tr><tr><td>Peak Withstand Current<\/td><td>30kA<\/td><td>63kA<\/td><td>105kA<\/td><\/tr><tr><td>Protection Class<\/td><td>IP30<\/td><td>IP30<\/td><td>IP30<\/td><\/tr><tr><td>Standard Cabinet Dimension<\/td><td>2200\u00d71000\u00d7600mm<\/td><td>2200\u00d71000\u00d7600mm<\/td><td>2200\u00d71200\u00d7800mm<\/td><\/tr><tr><td>Matching Transformer Capacity<\/td><td>\u22641000kVA<\/td><td>1000~2000kVA<\/td><td>\u22652000kVA<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">4. Working Principle<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Power from the main busbar of the low-voltage system enters the feeder cabinet through top copper busbars. Each independent branch is controlled by a dedicated MCCB, which distributes power to different terminal loads via underground cables.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Normal operation: Each branch operates independently to supply power to designated equipment without mutual interference.<\/li>\n\n\n\n<li>Fault protection: Once overload, short circuit or leakage occurs on any branch, the corresponding MCCB trips automatically, only cutting off the faulty circuit without affecting the whole bus section.<\/li>\n\n\n\n<li>Real-time monitoring: CT collects branch current signals, displaying operating data on the instrument panel and supporting remote uploading to power monitoring systems.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">5. Core Selling Points for Foreign Trade Website<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Complete model coverage: GGD1 for light loads, GGD2 universal standard type, GGD3 high-current heavy industrial type, flexible matching all transformer capacities.<\/li>\n\n\n\n<li>Multi-loop independent distribution design: Single-circuit fault will not paralyze the whole power supply system, greatly improving system stability.<\/li>\n\n\n\n<li>Multi-layer safety protection: Branch MCCB protection + integral cabinet grounding + IP30 anti-touch protection, eliminating live contact risks.<\/li>\n\n\n\n<li>Optimized heat dissipation structure: Upper and lower ventilation slots reduce internal temperature, supporting 24-hour continuous stable operation.<\/li>\n\n\n\n<li>Strong system compatibility: Freely combined with full set of GGD low-voltage cabinets to form single-section or double-section bus power distribution systems.<\/li>\n\n\n\n<li>Customized for global markets: Support 50\/60Hz frequency switching, English nameplates and instrument panels, adjustable loop quantity according to customer demands.<\/li>\n\n\n\n<li>Cost-effective fixed structure: Lower procurement and maintenance cost compared with withdrawable MNS\/GCS cabinets, widely recognized by global industrial and commercial customers.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">6. Application Scenarios<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GGD1 Feeder Cabinet: Small workshops, residential communities, small shopping malls, supporting transformers below 1000kVA.<\/li>\n\n\n\n<li>GGD2 Feeder Cabinet: Medium manufacturing plants, office buildings, commercial plazas, matching 1000~2000kVA transformers.<\/li>\n\n\n\n<li>GGD3 Feeder Cabinet: Heavy industry factories, data centers, central substations, photovoltaic energy storage stations with transformers above 2000kVA.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">7. Applicable Operating Environment<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Ambient temperature: -5\u2103 ~ +40\u2103, average temperature within 24 hours not exceeding +35\u2103.<\/li>\n\n\n\n<li>Altitude: \u22642000 meters above sea level.<\/li>\n\n\n\n<li>Humidity: Relative humidity \u226450% at 40\u2103; \u226490% at 20\u2103, no internal condensation.<\/li>\n\n\n\n<li>Installation conditions: Indoor dry and ventilated space, no corrosive gas, flammable dust and severe vibration; cabinet vertical inclination \u22645\u00b0.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Short Version (\u2248100 words for product list page)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">GGD series feeder cabinets are fixed low-voltage switchgears for 400V 50\/60Hz three-phase four-wire systems complying with IEC 60439-1. Built with 8MF steel frames and IP30 protection, they divide main bus power into multiple independent branches with MCCB overload &amp; short-circuit protection. GGD1\/2\/3 vary in short-circuit resistance and rated current for small, medium and large loads. Featuring independent cable compartments, remote monitoring and flexible system combination, they support overseas customization with low overall cost.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>GGD1\/GGD2\/GGD3 AC Low-Voltage Power Distribution Cabinet (Feeder Cabinet) 1. Product Overview GGD series feeder cabinet is fixed-type low-voltage distribution switchgear [&hellip;]<\/p>\n","protected":false},"featured_media":1993,"menu_order":0,"template":"","cxb_product_category":[15],"cxb_product_tag":[],"class_list":["post-1672","cxb_products","type-cxb_products","status-publish","has-post-thumbnail","hentry","cxb_product_category-multi-axis-cutting-equipment"],"_links":{"self":[{"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/cxb_products\/1672","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/cxb_products"}],"about":[{"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/types\/cxb_products"}],"version-history":[{"count":2,"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/cxb_products\/1672\/revisions"}],"predecessor-version":[{"id":1996,"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/cxb_products\/1672\/revisions\/1996"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/media\/1993"}],"wp:attachment":[{"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/media?parent=1672"}],"wp:term":[{"taxonomy":"cxb_product_category","embeddable":true,"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/cxb_product_category?post=1672"},{"taxonomy":"cxb_product_tag","embeddable":true,"href":"https:\/\/www.zzanwke.com\/ja\/wp-json\/wp\/v2\/cxb_product_tag?post=1672"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}