Product Details
安装图.png)
技术图.png)
KYN28A-12 Metal-Clad Withdrawable Indoor Switchgear (Incoming Cabinet)
一、Basic Overview 基础概述
KYN28A-12 is a 12kV indoor medium voltage armored removable central switchgear, the core incoming cabinet of 10kV power distribution room, responsible for receiving external municipal 10kV power supply, overall protection, measurement and power distribution switching of the whole high-voltage system. Adopt fully isolated metal partition structure, equipped with VS1 vacuum circuit breaker trolley, complete five-prevention interlock function, suitable for industrial plants, commercial complex, substation and other power supply occasions, widely used in overseas English-version power equipment websites.
二、Main Internal Equipment Composition 内部主要设备组成
- VS1 Indoor Vacuum Circuit Breaker Trolley The core switching and protection device of the incoming cabinet, installed in the middle trolley compartment. Upper contact connects main busbar, lower contact connects incoming cable. It realizes manual/electric closing & opening, with overload, short-circuit instantaneous breaking function.
- Current Transformer CT Series installed on the lower cable side of circuit breaker, collect three-phase current signals, transmit to protection relay and energy meter for metering and fault protection.
- Earthing Switch Installed in cable chamber, mechanical interlocked with circuit breaker trolley. When the trolley is withdrawn to test position, close earthing switch to discharge residual electricity for safe maintenance.
- High Voltage Live Display Sensor & Indicator Inductively detect live status of primary loop, display warning signal on cabinet door to remind staff of high voltage danger.
- Main Bus Bar & Branch Copper Busbar TMY copper busbar with insulation sheath, connect incoming cabinet to PT cabinet, outgoing cabinet, realize power transmission to each cabinet.
- Microcomputer Comprehensive Protection Relay Secondary core control unit, receive CT sampling signal, set over-current, quick-break, zero-sequence earth fault protection, send trip signal to vacuum breaker under fault condition.
- Secondary Terminal Block, Control Buttons, Indicator Lights Mounted on front upper instrument room, realize local manual operation, status display, fault alarm.
- Pressure Relief Channel & Arc-proof Partition Top pressure relief cover, independent metal partition for bus room, trolley room and cable room, prevent arc expansion during short-circuit fault.
三、Core Functions of Incoming Cabinet 进线柜核心功能
- Total Power Access Control Receive 10kV high voltage power from external grid, act as the general power switch of the whole high-voltage system, control the power supply of all downstream high-voltage cabinets.
- Full-circuit Fault Protection Vacuum breaker + comprehensive protection device cooperate to cut off circuit rapidly under short circuit, overload, single-phase earthing fault, avoid equipment burnout and large-area power failure.
- Safe Maintenance & Discharge Protection Matched earthing switch and five-prevention mechanical interlock, forbid live earthing, forbid drawing trolley with load, eliminate misoperation risk.
- Real-time Operation Monitoring Collect voltage, current, power data via CT, upload operating parameters to power monitoring system through communication module, support remote monitoring for unattended power station.
- Isolation & Arc Suppression Safety Protection Four-compartment fully isolated structure limits fault arc inside single compartment; top pressure relief device releases high temperature gas to prevent cabinet explosion.
- Whole Cabinet Grounding Protection Cabinet shell, all metal partitions, CT, earthing switch reliably connect to station grounding grid, prevent electric shock accident caused cabinet leakage.
四、Application Advantages (For English Website Display) 产品优势(适合英文网站宣传)
- Compact central trolley design, small floor space, convenient trolley replacement without power cut.
- High breaking capacity vacuum circuit breaker, long service life, low maintenance cost.
- Complete 5 anti-misoperation interlock system, high safety performance.
- Independent arc-proof compartment, high anti-short-circuit capacity.
- Support RS485 communication, compatible with intelligent power monitoring system.
- IP4X protection grade, anti-dust and anti-moisture, stable operation in indoor harsh environment.
五、Standard Technical Parameters 标准技术参数
- Rated Voltage: 12kV
- Rated Frequency: 50Hz
- Rated Current of Main Busbar: 630A / 1250A / 1600A / 2000A / 2500A / 3150A
- Rated Short-circuit Breaking Current: 20kA / 25kA / 31.5kA
- Protection Grade: IP4X (cabinet body)
- Operating Temperature: -10℃ ~ +40℃

主图.png)
主图.png)
主图.png)
