{"id":1812,"date":"2026-09-21T17:55:16","date_gmt":"2026-09-21T09:55:16","guid":{"rendered":"https:\/\/www.zzanwke.com\/?post_type=cxb_products&#038;p=1812"},"modified":"2026-09-28T16:44:30","modified_gmt":"2026-09-28T08:44:30","slug":"vs1-outdoor-vacuum-circuit-breaker","status":"publish","type":"cxb_products","link":"https:\/\/www.zzanwke.com\/de\/products\/vs1-outdoor-vacuum-circuit-breaker\/","title":{"rendered":"VS1 Outdoor Vacuum Circuit Breaker"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"700\" height=\"393\" src=\"https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/\u9ad8\u538b\u5143\u4ef6-VS1\u6746\u4e0a\u5b89\u88c5\u56fe.png\" alt=\"\" class=\"wp-image-1894\" srcset=\"https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/\u9ad8\u538b\u5143\u4ef6-VS1\u6746\u4e0a\u5b89\u88c5\u56fe.png 700w, https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/\u9ad8\u538b\u5143\u4ef6-VS1\u6746\u4e0a\u5b89\u88c5\u56fe-18x10.png 18w, https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/\u9ad8\u538b\u5143\u4ef6-VS1\u6746\u4e0a\u5b89\u88c5\u56fe-500x281.png 500w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"700\" height=\"393\" src=\"https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/\u9ad8\u538b\u5143\u4ef6-VS1\u5e94\u7528\u56fe.png\" alt=\"\" class=\"wp-image-1896\" srcset=\"https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/\u9ad8\u538b\u5143\u4ef6-VS1\u5e94\u7528\u56fe.png 700w, https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/\u9ad8\u538b\u5143\u4ef6-VS1\u5e94\u7528\u56fe-18x10.png 18w, https:\/\/www.zzanwke.com\/wp-content\/uploads\/2026\/09\/\u9ad8\u538b\u5143\u4ef6-VS1\u5e94\u7528\u56fe-500x281.png 500w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">VS1 Outdoor High Voltage Vacuum Circuit Breaker<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1. Product Overview<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">VS1 outdoor high voltage vacuum circuit breaker is a vital primary switching protection device for 10kV medium voltage power distribution systems. It adopts vacuum interrupter as arc extinguishing component, with spring operating mechanism, integrating circuit closing, load breaking, short-circuit and overload fault protection functions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This outdoor type VS1 breaker is designed for pole-mounted installation and outdoor substation layout. It features fully sealed vacuum arc chamber, reliable insulation performance, pollution-resistant outer shell, low maintenance cost and long service life. The product complies with IEC international standards, widely applicable to overhead distribution lines, pole transformers, photovoltaic power collection circuits and municipal outdoor power grid projects worldwide.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Main Features<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Outdoor vacuum circuit breaker for 10kV distribution network<\/li>\n\n\n\n<li>High-performance vacuum interrupter, zero arc medium leakage<\/li>\n\n\n\n<li>Fast breaking speed, excellent short-circuit protection capacity<\/li>\n\n\n\n<li>Spring energy storage operating mechanism, stable mechanical performance<\/li>\n\n\n\n<li>Outdoor anti-pollution composite insulator, strong adaptability to harsh climate<\/li>\n\n\n\n<li>Compact integrated structure, convenient pole-mounted installation<\/li>\n\n\n\n<li>Visible isolation structure optional for maintenance safety<\/li>\n\n\n\n<li>Dual frequency design for 50Hz \/ 60Hz global power grids<\/li>\n\n\n\n<li>Low operation noise, less contact wear, maintenance-free vacuum chamber<\/li>\n\n\n\n<li>With mechanical interlock and electrical locking to avoid misoperation<\/li>\n\n\n\n<li>Support remote control and manual local operation<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">3. Technical Specifications<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Item<\/strong><\/td><td><strong>Standard Parameter<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Model<\/td><td>VS1 Outdoor Vacuum Circuit Breaker<\/td><\/tr><tr><td>Rated Voltage<\/td><td>12kV (10kV power system)<\/td><\/tr><tr><td>Rated Frequency<\/td><td>50Hz \/ 60Hz<\/td><\/tr><tr><td>Rated Normal Current<\/td><td>630A, 1250A<\/td><\/tr><tr><td>Rated Short-Time Withstand Current (1s)<\/td><td>20kA, 25kA, 31.5kA<\/td><\/tr><tr><td>Rated Peak Withstand Current<\/td><td>50kA, 63kA, 80kA<\/td><\/tr><tr><td>Arc Extinguishing Unit<\/td><td>Vacuum Interrupter<\/td><\/tr><tr><td>Insulator Type<\/td><td>Outdoor Composite Insulator<\/td><\/tr><tr><td>Operating Mechanism<\/td><td>Spring Energy Storage Mechanism<\/td><\/tr><tr><td>Installation Mode<\/td><td>Pole-mounted \/ Outdoor substation support frame<\/td><\/tr><tr><td>Control Mode<\/td><td>Manual operation + Remote electric control<\/td><\/tr><tr><td>Protection Function<\/td><td>Overload protection, short-circuit protection, line fault breaking<\/td><\/tr><tr><td>Applicable Environment<\/td><td>Outdoor, rainproof, dustproof, anti-pollution environment<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">4. Structure Description<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Component Name<\/strong><\/td><td><strong>Functional Description<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Vacuum Interrupter<\/td><td>Core arc extinguishing component, break fault current in vacuum environment<\/td><\/tr><tr><td>Composite Outdoor Insulator<\/td><td>Isolate high voltage live parts from ground, resist rain, dust and fog pollution<\/td><\/tr><tr><td>Spring Operating Mechanism<\/td><td>Store mechanical energy to realize fast closing and tripping action<\/td><\/tr><tr><td>Energy Storage Motor<\/td><td>Complete automatic spring energy storage for remote operation<\/td><\/tr><tr><td>Current Transformer Bushing<\/td><td>Optional built-in CT for metering and protection signal collection<\/td><\/tr><tr><td>Metal Sealed Housing<\/td><td>Protect internal components against outdoor rain and corrosion<\/td><\/tr><tr><td>Operation Control Terminal<\/td><td>Connect external control cabinet for remote opening &amp; closing<\/td><\/tr><tr><td>Mounting Base<\/td><td>Fixed bracket for installation on power pole or substation frame<\/td><\/tr><tr><td>Mechanical Locking Device<\/td><td>Prevent misoperation of closing under fault status<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">5. Working Principle<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The core arc extinguishing medium of VS1 outdoor circuit breaker is high vacuum inside the interrupter.<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>Closing state: Moving and static contacts inside vacuum tube are tightly connected, the high voltage circuit conducts normally to transmit load current.<\/li>\n\n\n\n<li>Tripping state: When overload, short-circuit or line fault occurs, the protection signal triggers the spring mechanism to separate contacts instantly. The vacuum environment can rapidly extinguish electric arc without arc re-ignition, cutting off fault circuit reliably.<\/li>\n\n\n\n<li>After breaking fault current, the vacuum interrupter keeps insulation performance, ready for next switching cycle.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">The outdoor composite insulator isolates high voltage parts from ground, ensuring safe operation under outdoor rainy, dusty and high humidity conditions. Built-in CT can collect line current signals to match protection relays for automatic fault tripping.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. Application Scope<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">VS1 outdoor vacuum circuit breaker is widely used in the following power occasions:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10kV overhead distribution lines<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pole-mounted transformer power supply points<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Outdoor compact distribution substation<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Photovoltaic and wind power outdoor collection lines<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Municipal power grid reconstruction projects<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industrial park outdoor power distribution station<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rural power transmission network<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Commercial district outdoor feeder cabinet matching equipment<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7. Installation Instructions<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>Check the whole breaker before installation, confirm no damage, crack or deformation on composite insulator and metal shell; verify rated parameters match project design.<\/li>\n\n\n\n<li>Fix the equipment firmly on reinforced power pole or metal support frame with special anti-rust fasteners.<\/li>\n\n\n\n<li>Keep enough safety clearance between high voltage terminals and ground or other metal structures.<\/li>\n\n\n\n<li>Connect overhead cable terminals tightly to avoid contact overheating during long-term operation.<\/li>\n\n\n\n<li>Wire the control loop correctly according to wiring diagram, test remote electric closing and tripping function.<\/li>\n\n\n\n<li>Conduct mechanical operation test repeatedly to ensure smooth energy storage, closing and tripping without jamming.<\/li>\n\n\n\n<li>Complete insulation withstand test and protection linkage test before power transmission.<\/li>\n\n\n\n<li>Regularly check insulator surface dirt, mechanism lubrication and terminal tightness during operation.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">8. Safety Warnings<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>All installation, commissioning and maintenance work must be completed by certified professional electrical technicians.<\/li>\n\n\n\n<li>Cut off all upstream power supply, carry out power failure, test and grounding operation before inspecting the breaker.<\/li>\n\n\n\n<li>Do not touch high voltage terminals and insulator surface when the equipment is energized.<\/li>\n\n\n\n<li>Strictly prohibit disassembling vacuum interrupter without professional equipment; damaged vacuum tube cannot be reused.<\/li>\n\n\n\n<li>Stop operation immediately if insulator flashover, abnormal noise or shell overheating appears, cut off power for full inspection.<\/li>\n\n\n\n<li>Avoid violent impact on composite insulator during transportation and installation to prevent hidden cracks.<\/li>\n\n\n\n<li>Keep product nameplate and technical drawing for later maintenance reference.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">9. Ordering Information<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Please provide the following technical requirements when placing orders:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>Rated normal current<\/li>\n\n\n\n<li>Rated short-time withstand current<\/li>\n\n\n\n<li>With or without built-in current transformer<\/li>\n\n\n\n<li>Control mode (manual \/ remote electric control)<\/li>\n\n\n\n<li>Pole-mounted installation dimension limit<\/li>\n\n\n\n<li>Order quantity<\/li>\n\n\n\n<li>Applicable international standard (IEC as default for overseas export)<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">10. Packing &amp; Export Note<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Each VS1 outdoor vacuum circuit breaker is wrapped with thick shockproof bubble film, then fixed in solid fumigated wooden export case. Steel strips reinforce the wooden case to resist collision, vibration and dampness during long-distance sea, land and air transportation. Neutral English labels without any brand logo are attached on outer package, convenient for overseas customs clearance and warehouse storage.<\/p>","protected":false},"excerpt":{"rendered":"<p>VS1 Outdoor High Voltage Vacuum Circuit Breaker 1. Product Overview VS1 outdoor high voltage vacuum circuit breaker is a vital [&hellip;]<\/p>\n","protected":false},"featured_media":1897,"menu_order":0,"template":"","cxb_product_category":[14,30],"cxb_product_tag":[],"class_list":["post-1812","cxb_products","type-cxb_products","status-publish","has-post-thumbnail","hentry","cxb_product_category-sheet-metal-equipment","cxb_product_category-high-voltage-primary-components"],"_links":{"self":[{"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/cxb_products\/1812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/cxb_products"}],"about":[{"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/types\/cxb_products"}],"version-history":[{"count":2,"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/cxb_products\/1812\/revisions"}],"predecessor-version":[{"id":1898,"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/cxb_products\/1812\/revisions\/1898"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/media\/1897"}],"wp:attachment":[{"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/media?parent=1812"}],"wp:term":[{"taxonomy":"cxb_product_category","embeddable":true,"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/cxb_product_category?post=1812"},{"taxonomy":"cxb_product_tag","embeddable":true,"href":"https:\/\/www.zzanwke.com\/de\/wp-json\/wp\/v2\/cxb_product_tag?post=1812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}